While small hairline cracks are often non-structural, determining if a foundation crack is “too big” depends on its characteristics and the underlying cause. In the Denver Front Range, our expansive clay soils can swell up to 10% in volume, leading to significant structural movement.
We recommend an evaluation at the first sign of trouble, especially if you notice the following warning signs alongside cracking:
Our Repair Approach
The severity of the crack determines our professional strategy. For non-structural cracks primarily intended to stop water leaks, we may use Crack Chasing & Sealing with high-performance, flexible sealants that withstand Colorado’s freeze-thaw cycles.
For larger, structural cracks that threaten the integrity of the home, we utilize Epoxy Injection to restore the concrete’s original load-bearing strength. In cases of significant soil movement, we install Helical Piers to stabilize the structure by reaching stable soil depths, often averaging 17 feet.
Because site conditions vary widely, accurate diagnosis requires a professional on-site evaluation by our trained, certified installers. Consult a licensed structural engineer or qualified professional for definitive diagnosis and design recommendations.
The cost of helical pier installation is influenced by several site-specific and technical variables. Because no two properties have identical ground conditions or structural needs, pricing is typically determined through custom quotes rather than flat rates. Key factors influencing the…
The manufacturing, testing, and installation of commercial helical piers are governed by several specific ASTM International standards to ensure structural integrity and predictable performance. These include:ASTM F3143-18: This serves as the primary standard for commercial helical piles, establishing minimum requirements…
Based on the provided content, there are eight primary causes of foundation failure and structural distress:Poor Drainage and Water Accumulation: This occurs when water pools near the foundation due to improper grading, clogged gutters, or short downspout extensions, which can…
The load capacities for commercial helical piles are determined through a systematic combination of engineering analysis and real-time installation data. Rather than a single fixed value, capacity is verified using the following methods:Torque-to-Capacity Correlation: During installation, rotary equipment records the…
Under a Tower Hill Insurance policy, damage must meet a specific structural threshold to qualify as a covered sinkhole loss. Coverage typically applies to the building and its foundation when settlement or cracking is directly attributed to sinkhole activity (subterranean…